Indirect Lighting LED Range

UD-WM-600-23W-3K

UD-WM-600-23W-3K

Up/Down

Based on a 2.7m Ceiling & 0.8 light loss factor + UD-WM-600-24W-3K

Room size Units Equally Spaced Lux Ave Specific Connected Loads
3 x 3m 2 = 149 3.48 w/m2 = 2.33 w/m2/100lux
3.5 x 4m 2 = 103 2.17 w/m2 = 2.12 w/m2/100lux
2 x 15m 2 = 115 2.16 w/m2 = 2.27 w/m2/100lux

For the largest room Proportion of point with less than 400lux (for IEQ-7) = 100%

Up/Down Room Display
Up/Down Room Map
Up/Down Corridor Display Up/Down Corridor Map

LG-WM-600-19W-3K

LG-WM-600-19W-3K

The Ledge

Based on a 2.7m Ceiling & 0.8 light loss factor + LG-WM-600-24W-3K

Room size Units Max spacing Lux Ave Specific Connected Loads
3 x 3m 1 = 80 3.08 w/m2 = 3.79 w/m2/100lux
3 x 4m 2 = 121 4.63 w/m2 = 3.83 w/m2/100lux
9.6 x 9.6m 16 1m 165 4.82 w/m2 = 2.92 w/m2/100lux
20 x 2m 6 3.5m 103 4.16 w/m2 = 4.04 w/m2/100lux

For the largest room Proportion of point with less than 400lux (for IEQ-7) = 100%

Mounting & Power Entry Details

The Ledge Mounting and Power Entry Details
The Ledge Room Display
The Ledge Room Map
The Ledge Corridor Display The Ledge Corridor Map