Linear 100 LED Range

LimeLite Optics Diffuser LIN-T-LO-1200-23W-4K

LIN-T-LO-1200-23W-4K

Plaster Recess

Tee-Bar

Surface Mount

KLean 44

RH125

1200mm long luminaires
Based on a 2.7m Ceiling & 0.8 light loss factor – Dialux generated figures

Room size Units Max spacing Lux Ave Specific Connected Loads
3 x 3m 2 = 344 5.08 w/m2 = 1.48 w/m2/100lux
3 x 4m 3 = 407 5.72 w/m2 = 1.41 w/m2/100lux
9.6 x 9.6m 16 2.4 x 2.4m 354 3.97 w/m2 = 1.12 w/m2/100lux
24 x 30m 100 2.4 x 3m 327 3.18 w/m2 = 0.97 w/m2/100lux

For the largest room Proportion of point with less than 400lux (for IEQ-7) = 100%

LIN-TWL-1200-23W-4K

LIN-TWL-1200-23W-4K

Plaster Wall Washer

Tee-Bar Wall Washer

Surface Mount Wall Washer

Based on a 3m high wall (1m for a 3m wall)

Units Mounting Lux Ave
2 1/3 wall height 150

LimeLite Optics Diffuser LIN-T-LO-1200-44W-90+CRI

LIN-T-LO-1200-44W-90+CRI

Plaster Recess

Tee-Bar

Surface Mount

KLean 44

RH125

1200mm long luminaires
Based on a 2.7m Ceiling & 0.8 light loss factor – Dialux generated figures

Room size Units Max spacing Lux Ave Specific Connected Loads
3 x 3m 2 = 376 10.12 w/m2 = 2.69 w/m2/100lux
3 x 4m 3 = 464 11.38 w/m2 = 2.45 w/m2/100lux
9.6 x 9.6m 16 2.4 x 2.4m 417 7.9 w/m2 = 1.90 w/m2/100lux
24 x 30m 100 2.4 x 3m 371 6.32 w/m2 = 1.71 w/m2/100lux

For the largest room Proportion of point with less than 400lux (for IEQ-7) = 74.71%

Extra Low Glare Diffuser LIN-T-XLG-1200-36W-4K

LIN-T-XLG-1200-36W-4K

Plaster Recess

Tee-Bar

Surface Mount

KLean 44

RH125

1200mm long luminaires
Based on a 2.7m Ceiling & 0.8 light loss factor – Dialux generated figures

Room size Units Max spacing Lux Ave Specific Connected Loads
3 x 3m 2 = 306 5.08 w/m2 = 1.66 w/m2/100lux
3 x 4m 3 = 362 5.72 w/m2 = 1.58 w/m2/100lux
9.6 x 9.6m 16 2.4 x 2.4m 328 3.97 w/m2 = 1.21 w/m2/100lux
24 x 30m 100 2.4 x 2.7m 322 3.53 w/m2 = 1.10 w/m2/100lux

URGmax: 23

WedgeLED Diffuser WedgeLed Range

WedgeLed Range Photometrics

Plaster Recess

Tee-Bar

Surface Mount

1200mm long luminaires
Based on a 2.7m Ceiling & 0.8 light loss factor – Dialux generated figures

Room size Units Max spacing Lux Ave Specific Connected Loads
3 x 3m 2 = 310 6.41 w/m2 = 2.07 w/m2/100lux
3 x 4m 3 = 375 7.22 w/m2 = 1.92 w/m2/100lux
9.6 x 9.6m 16 2.4 x 2.4m 331 5.01 w/m2 = 1.51 w/m2/100lux
24 x 27m 100 2.4 x 2.7m 335 4.45 w/m2 = 133 w/m2/100lux

For the largest room Proportion of point with less than 400lux (for IEQ-7) = 100%

Very high Verticals Could be retail shelves, libraries or corridors

375 Lux average on walls

Walls & Ceiling well lit with uniform lighting Office Large Area 2.7m x 2.4m x 2.7m Ceiling Height

372 Lux average on work plane

WedgeLED Lux average Wide Corridor

100 Lux average on floor